Key to Fig. 2:
ASpace
A
1
Boiler return clearance
A
2
/A
VSL
Boiler flow clearance
A
3
Drain clearance
A
4
Condensate outlet clearance
A
AA
Flue gas connection clearance
A
B
Base frame width
A
GAS
Gas connection clearance
A
RLU
Combustion air connection clearance
AA Flue gas outlet
AKO Condensate connection
B Width of boiler including casing
B
GR
Base frame width
D
AA
Inside Ø of flue gas outlet
EL Cold water inlet/drain
H
83xx
Control unit height CC83xx
H
MX25
Control unit height MX25
H
AA
Flue outlet height
H
AS
Vertical height of flue connector (optional)
H
AKO
Condensate outlet height
H
GAS
Gas connection height
Z Clearance rear gas connection
H
EL
Drain height
H
K
Boiler height
H
RK
Boiler return (low temperature return) height
H
RLU
Combustion air connection height
Y Clearance rear combustion air connection
H
VK
Boiler flow height
H
VSL
Flow safety pipe height
L Length of boiler including casing
L
K
Boiler length
VK Boiler flow
VSL Pressure relief valve and flow safety pipe connections (for
open vented systems)
Table 3 Measurements and connection dimensions
Boiler size (output in kW)
Unit 350
1)
1) Right-hand version
350
2)
2) Left-hand version
400
1)
400
2)
500
1)
500
2)
Length L mm 1903 1903 1903 1903 2088 2088
Length L
K
mm 1832 1832 1832 1832 2017 2017
Width B mm 803 803 803 803 803 803
Width B
GR
mm 684 684 684 684 684 684
Dimension A
B
mm 1880 1880 1880 1880 1968 1968
Clearance A mm 50 50 50 50 50 50
Height H
K
mm 1582 1582 1582 1582 1582 1582
Height H
AA
mm 855 855 855 855 874 874
Dimension A
AA
mm 396 406 396 406 396 406
Height H
AKO
mm 171 171 171 171 171 171
Dimension A
4
mm 267 277 267 277 267 277
Height H
EL
mm 177 177 177 177 177 177
Dimension A
3
mm 175 632 175 632 175 632
Height H
RLU
mm 1662 1662 1662 1662 1662 1662
Dimension Y mm 1314 1314 1314 1314 1502 1502
Dimension A
RLU
mm 282 282 282 282 282 282
Height H
VK
mm 1414 1414 1414 1414 1414 1414
Dimension A
2
/A
VSL
mm 196 605 196 605 196 605
Height H
VSL
mm 1480 1480 1480 1480 1480 1480
Height H
RK
mm 620 620 620 620 620 620
Dimension A
1
mm 196 605 196 605 196 605
Dimension A
GAS
mm 118 118 118 118 118 118
Height H
GAS
mm 1670 1670 1670 1670 1670 1670
Dimension Z mm 1227 1227 1227 1227 1416 1416
Internal flue gas outlet
ØAA
mm 251 +1.2/-0.5 251 +1.2/-0.5 251 +1.2/-0.5 251 +1.2/-0.5 251 +1.2/-0.5 251 +1.2/-0.5
RLU connection mm 200 ± 0.5 200 ± 0.5 200 ± 0.5 200 ± 0.5 200 ± 0.5 200 ± 0.5
Connection
VK and RK
DN/mm 100 100 100 100 100 100
Connection
Ø VSL
inch R 2’’ R 2’’ R 2’’ R 2’’ R 2’’ R 2’’
Connection Ø GAS inch R 2’’ R 2’’ R 2’’ R 2’’ R 2’’ R 2’’
Condensate
connection
inch
(DN/mm)
¾‘’
(DN20)
¾‘’
(DN20)
¾‘’
(DN20)
¾‘’
(DN20)
¾‘’
(DN20)
¾‘’
(DN20)
Height
83xx
mm 1822 1822 1822 1822 1822 1822
Height
MX25
mm 1724 1724 1724 1724 1724 1724