EasyManua.ls Logo

Bosch Condens 8300i W - Checking the Non-Return Valve in the Mixing Device; Checking the Electrical Wiring; Checking the Expansion Vessel; Check the Strainer in the Cold Water Pipe and the Turbine

Bosch Condens 8300i W
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inspection and maintenance
43
Condens 8300i W – 6721841531 (2022/10)
9.10 Checking the non-return valve in the mixing device
1. Disconnect the transformer.
2. Loosen the screw [1] and nut [2] on the mixing device.
3. Remove the mixing device.
Fig. 50 Removing the mixing device
1. Remove the non-return valve.
2. Check the non-return valve for contamination and cracks.
Fig. 51 Non-return valve in the mixing device
Install the non-return valve.
Install the mixing device.
Tighten the screw and nut ([1] and [2], Fig. 50) on the mixing device
with 5.5+0.5 Nm.
9.11 Checking the electrical wiring
Check the electrical wiring for mechanical damage.
Replace defective cables.
9.12 Checking the expansion vessel
The expansion vessel must be checked every year.
Depressurise the appliance.
Adjust the pre-charge pressure of the expansion vessel to the static
head of the heating system, if necessary.
9.13 Check the strainer in the cold water pipe and the
turbine
1. Remove the clip.
2. Loosen the cold water pipe.
3. Pull the strainer out of the cold water pipe and check for
contamination.
Fig. 52 Removing the strainer from the cold water pipe
1. Remove the clip.
2. Pull out the turbine.
Fig. 53 Removing the turbine at the cold water pipe
Select the volumetric flow rate of the turbine with service function 1-
b2.
Blow in the flow direction of the turbine.
If nothing appears on the display, replace the turbine.
2.
2.
1.
3.
3.
1
2
0010040965-001
1.
2.
0010018136-002
0010031704-002
2.
3.
1.
1.
2.
0010033509-001

Table of Contents