Conettix DX4020 | Installation Guide | Trademarks
.
Bosch Security Systems, Inc. | 1/09 | F01U045288-05 3
Trademarks
Microsoft
®
and Windows
®
are either registered
trademarks or trademarks of Microsoft
Corporation in the United States and/or other
countries.
Lantronix
®
is a registered trademark of Lantronix
Corporation, registered in the U.S. and other
countries.
XPort
with its patent-pending technology is a
trademark of Lantronix, Inc.
UL Requirements
For Underwriters Laboratories, Inc. (UL)
Listed fire Installations, ensure that the
shared on-premises communications
equipment is UL Listed for information
technology equipment.
1. Set the parameters in the RADXAUX1 or
GV2AUX section of the control panels
(Table 1).
The GV2AUX handler is used for GV2
Series control panels. The RADXAUX1
handler is used for G Series control panels.
Table 1: Control Panel RADXAUX1 or GV2AUX
UL Parameters
Control Panel on Protected Premises
1
UL1610 Line Security
Intrusion System
Installations
RADXAUX1
GV2AUX
Parameter
No Digital
Dialer
Backup
Digital
Dialer
Backup
UL864 Fire
Systems
Installations
2
Poll Rate 75 sec 240 sec 75 sec
ACK Wait 13 sec 13 sec 13 sec
Retry Count 5 5 5
1 For local annunciation, G Series control panels require
Firmware Version 6.9 or higher. GV2 Series control panels
require Version 7.04 or later.
2 Install the system according to NFPA-72.
2. Add a Telnet password to the DX4020
communications protocol. To complete the
configuration, refer to Section 6.5 Using Telnet to
Complete Configuration, page 11.
Keep your password for future reference.
Certifications and Approvals
UL Standards
UL294, Access Control Systems Units
UL864, UL Commercial Fire Alarm signaling
UL365, Police Station Burglar Alarm Units and
Systems
UL609, Local Burglar Alarm Units and Systems
UL985, Household Fire Warning System Units
UL1023, Household Burglar-alarm System Units
UL1076, Proprietary Burglar Alarm Units and
Systems
UL1610, Central Station Burglary, Line Security
ULC Standards
CAN/ULC-S303-M91, Local Burglar Alarm Units
and Systems
CAN/ULC-S304-M88, Central and Monitoring
Station Burglar Alarm Units
CAN/ULC-S545, Residential Fire Warning System
Control Units
ULC/ORD-C1076-M1986, Proprietary Burglar
Alarm Units and Systems Communicator
ULC-C1023-1974, Household Burglar Alarm
Systems
Approvals
CSFM
NF A2P Type 2 Certification number:
122000076-05
FM*
* When used with the Conettix D6600
Communications Receiver/Gateway.
Refer to the D6200 Software Operation
and Installation Guide (P/N: 4998154991)
to configure the D6600/D6100i
Communication Receiver/Gateway to
receive UL Listed communications from a
DX4020.

Related product manuals