UL Requirements
For Underwriters Laboratories, Inc. (UL)
Listed fire Installations, ensure that the
shared on-premises communications
equipment is UL Listed for information
technology equipment.
1. Set the parameters in the RADXAUX1 or
GV2AUX section of the control panels
(Table 1).
The GV2AUX handler is used for GV2
Series control panels. The RADXAUX1
handler is used for G Series control panels.
Table 1: Control Panel RADXAUX1 or GV2AUX
UL Parameters
Control Panel on Protected Premises
1
UL1610 Line Security
Intrusion System
Installations
RADXAUX1
GV2AUX
Parameter
No Digital
Dialer
Backup
Digital
Dialer
Backup
UL864 Fire
Systems
Installations
2
Poll Rate 75 sec 240 sec 75 sec
ACK Wait 13 sec 13 sec 13 sec
Retry Count 5 5 5
1 For local annunciation, G Series control panels require
Firmware Version 6.9 or higher. GV2 Series control panels
require Version 7.04 or later.
2 Install the system according to NFPA-72.
2. Add a Telnet password to the DX4020
communications protocol. To complete the
configuration, refer to Section 6.5 Using Telnet to
Complete Configuration, page 11.
Keep your password for future reference.
Certifications and Approvals
UL Standards
• UL294, Access Control Systems Units
• UL864, UL Commercial Fire Alarm signaling
• UL365, Police Station Burglar Alarm Units and
Systems
• UL609, Local Burglar Alarm Units and Systems
• UL985, Household Fire Warning System Units
• UL1023, Household Burglar-alarm System Units
• UL1076, Proprietary Burglar Alarm Units and
Systems
• UL1610, Central Station Burglary, Line Security
ULC Standards
• CAN/ULC-S303-M91, Local Burglar Alarm Units
and Systems
• CAN/ULC-S304-M88, Central and Monitoring
Station Burglar Alarm Units
• CAN/ULC-S545, Residential Fire Warning System
Control Units
• ULC/ORD-C1076-M1986, Proprietary Burglar
Alarm Units and Systems Communicator
• ULC-C1023-1974, Household Burglar Alarm
Systems
Approvals
•
• CSFM
• NF A2P Type 2 Certification number:
122000076-05
• FM*
* When used with the Conettix D6600
Communications Receiver/Gateway.
Refer to the D6200 Software Operation
and Installation Guide (P/N: 4998154991)
to configure the D6600/D6100i
Communication Receiver/Gateway to
receive UL Listed communications from a
DX4020.