D7212GV2 | Operation and Installation Guide | 13.0 Programmer Connections
.
Bosch Security Systems, Inc. | 5/05 | F01U003805B 51
13.0 Programmer Connections
13.1 Programmer Connector
Refer to the D5200 Operation Manual
(P/N: 74-06176-000) for complete information on using
the D5200 programmer.
To connect and disconnect the programmer:
1. Lock the Reset Pin (Figure 24).
2. Connect the D5200 Data/Power cord to the
programming connector on the control panel.
3. Perform the desired programming function (send
or receive program).
4. Disconnect the programmer.
Figure 24: Reset Pin
Reset Pin
Disable All Except Battery
Charging And Programming
PERIPHERAL DEVICE CONNECTIONS
RED POWER +
YELLOW DATA BUS A
GREEN DATA BUS B
BLACK COMMON
32
31
30
29
1
2
1 - Reset Pin locked (closed)
2 - Reset Pin normal (open) for normal control
panel operation
13.2 Programmer Access Reports
When a program is sent to the control panel, the
control panel sends a Prog Access OK report ten
seconds after the handler exits or when the
programmer disconnects. The prompt in routing must
be programmed Yes to send this report.