D7212GV3 | Program Entry Guide | 6.0 AUXPARM EN | 116
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
RPS Port Number
Default: 7750
Selection: 1 to 65535
This prompt specifies the destination port for
outgoing RPS session requests to the IP address
specified in RPS IP Address #.
Keypad Programming of RPS IP Address # and RPS
PortNumber
D1255
1. Refer to Figure 1 on page 6 to access Keypad
Programming and navigate to the RPS
PARAMETERS option. Press [ENT].The keypad
shows the RPS PASSCODE option and the
currently configured passcode.
2. Press [NEXT] twice to advance to the RPS IP
ADDRESS option and press [ENT]. The currently
configured IP address shows.
3. An invisable editing cursor is enabled for the first
byte.
4. The [PREV] button acts as a [Backspace] key.
Press [PREV] to delete the characters of the
byte, and then enter the new byte numbers, or
press [NEXT] to move to the next byte.
The keypad does not accept invalid byte
numbers.
5. Repeat Step 4 to enter the correct numbers for
each byte.
6. Press [ENT] to save the changes.
When the keypad reads Parameter Saved, your
selection is configured.
7. When the keypad reads RPS IP ADDRESS,
press [NEXT] to advance to the RPS IP PORT
option. The keypad shows the currently
configured port number.
8. Press [ENT] to change the port number.
9. The [PREV] button acts as a [Backspace] key.
Press [PREV] to delete the characters of the port
number and then enter the new port number.
10. Press [ENT] to save the changes.
When the keypad reads PARAMETER SAVED, your
selection is configured.
D1260
1. Refer to Figure 2 on page 7 to access Keypad
Programming and navigate to the RPS
Parameters option. Press [ENT].The keypad
shows the RPS Passcode option and the
currently configured passcode.
2. Press Phone Number softkey. The keypad
shows the currently configured phone number
and the IP Address option.
3. Press the IP Address softkey. The currently
configured IP address shows.
4. Press the Edit softkey to change the IP address.
5. The Previous and Next softkeys move the
cursor through the bytes. The Backspace
softkey allows you to erase characters. The
Clear softkey allows you to clear the entire IP
address. Use the softkeys and the number
buttons on the keypad to enter the new IP
Address.
The keypad does not accept invalid byte
numbers.
6. Press the Save softkey to save the changes.
When the keypad reads Parameter Saved, your
selection is configured.
7. When the keypad reads RPS IP Address, press
the Port Number softkey. The keypad shows the
currently configured port number.
8. Press the Edit softkey to change the port
number.
9. The Backspace softkey allows you to erase
characters. The Clear softkey allows you to clear
the entire port number. Use the softkeys and the
number buttons on the keypad to enter the new
port number.
Press the Exit softkey to save the changes.