D7212GV3 | Program Entry Guide | 2.0 Panel and Area Wide Parameters EN | 17
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Burglar Reports
Select Yes to send a report when the event occurs.
Table 7: Burglar Reports
Report Selections Report Description
R# Alarm Yes, No Burglar Alarm Event
R# Burg
Restore
Yes, No
Non-fire restoral from
trouble, missing, or
supervisory
R# Duress Yes, No Duress
R# Missing
Alarm
Yes, No Missing Alarm point
R# Usr Code
Tmpr
Yes, No User code tamper
R# Trouble
Report
Yes, No Trouble Event
R# Missing
Trbl
Yes, No
Missing Trouble
Event
R# Non Fire
Suprv
Yes, No
Non-fire Supervision
Event
R# Point Bus
Fail
Yes, No Point bus failure
R# Point Bus
Rstl
Yes, No
Restoral of point bus
after failure
R# Non Fire
Cncl
Yes, No
Canceled non-fire
alarm
R# Alarm
Restore
Yes, No
Non-fire restoral from
alarm
R# Sup
Missing
Yes, No Supervisory missing
R# Unverified
Evt
Yes, No
Unverified Events for
Cross Points
R# Unverified Evt is sent when a single
point programmed in Cross Point Group
faults into an alarm condition, then
restores before the Cross Point Time
elapses.
R# Unverified Evt encompasses both
Fire and Non-fire points, but is not related
to the A# Verify Time used for smoke
detectors.
The D7212GV3 logs a Ground Fault
Event as Trouble Point 256.
Restoral Reports are not sent if the
control panel resets after a point is
bypassed and then unbypassed. This is
true for both Fire and Non-fire points.
User Reports
Selecting Yes enables a report to be sent when the
event occurs.
Table 8: User Reports
Report
Selection
s
Report Description
R# Point
Bypass
Yes, No Point Bypass Event
R# Forced
Point
Yes, No Forced Point Event
R# Point
Open
Yes, No Point Opening Event
R# Point
Close
Yes, No Point Closing Event
R# Forced
Arm
Yes, No Point Force Armed
R# Fail To
Open
Yes, No Fail to Open Event
R# Fail To
Close
Yes, No Fail to Close Event
R# Ext Clos
Tm
Yes, No
Extend Close Time
Event
R# Opening
Report
Yes, No Opening Events
R# Forced
Close
Yes, No
Point Forced Close
Event
R# Closing
Report
Yes, No Closing Events
R# FC
Perimeter Inst
Yes, No
Forced Close
Perimeter Instant
Armed Event
R# FC
Perimeter
Delay
Yes, No
Forced Close
Perimeter Delay
Armed Event
R# Perimeter
Inst Arm
Yes, No
Perimeter Instant
Armed Event
R# Perimeter
Delay Arm
Yes, No
Perimeter Delay
Armed Event
R# Send User
Text
Yes, No User text