D7212GV3 | Program Entry Guide | 2.0 Panel and Area Wide Parameters EN | 20
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Auto Function Reports
The following prompts support customized routing of
Auto Function Reports. Selecting Yes enables a
report to be sent when the event occurs.
Table 12: Auto-Function Reports
Report
Selection
s
Report Description
R# Sked
Executed
Yes, No
Sked Executed
Event
R# Sked
Changed
Yes, No
Sked Changed
Event
R# Execute
Fail
Yes, No
Fail to Execute
Event
RPS Reports
Selecting Yes enables sending a report when the
RPS Passcode Event occurs.
RPS Access Fail can indicate a wrong
RPS passcode when communicating
with the control panel or a valid RPS
session was terminated by a means
other than a Good-bye or Reset-bye
command. Remote Reset indicates a
Reset-bye command issued from RPS,
Fail to Call RPS indicates the control
panel called RPS but was unable to
connect.
Table 13: RPS Reports
Report Selections Report Description
R# Log
Threshold
Yes, No
Event log threshold
reached
R# Log
Overflow
Yes, No
Log is full, old events
are overwritten
R# Para
Changed
Yes, No
RPS Parameter
Change Event
R# RPS OK Yes, No
Successful RPS
Access Event
R# RPS Fail Yes, No
Failed Access RPS
Event
R# Remote
Reset
Yes, No Remote Reset Event
R# Program
OK
Yes, No
Successful Local
Programming Event
R# Program
Fail
Yes, No
Failed Local
Programming Event
Point Reports
Selecting Yes enables a report to be sent when the
event occurs.
Table 14: Point Reports
Report Selections
Report
Description
R# Service Start Yes, No
Reorts Service
Walk Test Start
Event
R# Service End Yes, No
Service Walk
Test End Event
R# Fire Walk St Yes, No
Fire Walk Start
Event
R# Fire Walk End Yes, No
Fire Walk End
Event
R# Walk Test St Yes, No
Walk Test Start
Event for Walk
Test and
Invisible Walk
Test
R# Walk Test End Yes, No
Walk Test End
Event for Walk
Test and
Invisible Walk
Test
R# Extra Point Yes, No
Extra Point
Event
R# Send Point
Text
1
Yes, No Point Text
R# RF Low Bat Yes, No
Low battery
conditions for
RF points
R# RF Low Bat
Res
Yes, No
Low battery
restoral
conditions for
RF points
1
Point text is always transmitted when using
network applications.