D7212GV3 | Program Entry Guide | 2.0 Panel and Area Wide Parameters EN | 45
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Cmd Center
Default: 1
Selection:
1 to 8
DIP Switch Setting
SDI CC#
1 2 3 4 5 6
1 ON ON ON ON -- ON
2 OFF ON ON ON -- ON
3 ON OFF ON ON -- ON
4 OFF OFF ON ON -- ON
5 ON ON OFF ON -- ON
6 OFF ON OFF ON -- ON
7 ON OFF OFF ON -- ON
8 OFF OFF OFF ON -- ON
Enter the keypad (CC) number for the SDI address you are programming. This number corresponds to the DIP
switch address settings shown.