D7212GV3 | Program Entry Guide | 2.0 Panel and Area Wide Parameters EN | 52
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
Area # Name Text
Default: Refer to the program record sheet
Selection:
Sixteen alphanumeric characters
Enter the text for this area's name. This text only
displays on the D1260 series keypads.
Custom Function
Default: 128
Selection:
128 to 131
Enter the Custom Function number you want to
program. You can program up to sixteen Custom
Functions, which are numbered 128 to 131.
Custom Functions 132 through 143 are
not available with D7212GV3.
CF### Text
Default: Refer to the program record sheet
Selection:
Sixteen alphanumeric characters.
Refer to Section 2.9.2 Area Text
on page 50 for valid character
entries.
Determines the menu text displayed at the keypad for
the custom function item. Use this text to represent
the functions performed by this menu item.
CF### Key Strokes
Table 19: CF### Key Strokes
Default:
Selection
:
Refer to the program record sheet
Up to 32 characters: 0 to 9, A, B, C, D, E
Selection D1255 Key
D1255
Faceplate
Label
D1260 Key
0 to 9 0 to 9 0 to 9
A [COMMAND]
[COMMAND*]
B [PREV]
(previous)
NA
C [ESC]
(escape)
MENU NA
D [NEXT] NA
E [ENT] (enter) YES [#ENTER]
C1* NA (softkey 1)
C2* NA (softkey 2)
C3* NA (softkey 3)
C4* NA (softkey 4)
C5* NA (softkey 5)
C6* NA (softkey 6)
C7* NA (softkey 7)
C8* NA (softkey 8)
* Softkey selections are stored as two keystrokes.
The keystrokes simulate any sequence of keystrokes
the user can perform at a keypad. You can program
up to 32 keystrokes for each Custom Function.
The scope of the keypad where you
access the Function List can affect the
way the Custom Function operates.