D7212GV3 | Program Entry Guide | 3.0 Passcodes, Access Credentials, and User Groups EN | 76
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
U### User Group
Default: 0
Selection: 0, 1 to 8
Create a group of up to 099 users whose
combinations can be enabled and disabled using an
automatic user window. This is the number entered
into the W# User Group for any active W# User
Window. Multiple windows can be programmed for
one user group (up to eight) within one 24-hour
period. For example, if User Group 1 has a window
running from 8:00 AM (start time) to 4:00 PM (stop
time), the users for that group can use their
passcodes only between that time. Between 4:00 PM
that day and 8:00 AM the next day, the users cannot
use their passcodes.
To enable this user’s passcode at all
times, leave U### User Group 0.
User Group Window times cannot be changed from
the keypad. When a window is assigned to a user
group, the users in that group rely on the window to
be active (within the start and stop times) for their
passcodes to function. The only way to disable the
window is by reprogramming the control panel from
the remote programming software (RPS).
U### Area 1 [through Area 4] Auth
Default: Refer to the program record sheet
Selection: 0 to 14
Assign an authority level to the user for this area.
A setting of 0 means the user has no authority in this
area.
U### Name
Default: Refer to the program record sheet
Selection: Sixteen alphanumeric characters
Enter Alphabetic-characters A to Z in capital letters
Period (.), comma (,), percent (%), parentheses [()],
equal (=), greater or less than (< >), exclamation (!),
braces ({}), apostrophe (’), carat (^), grave accent (`),
tilde (~), semi-colon (;), and colon (:) are not allowed.
Enter up to sixteen characters of text for this user
group.
Programming this group with a
departmental, team, or function name
identifies all the users in this group in a
function related manner, such as
ENGINEERING.
U### Mstr Site
Default: 255
Selection: 0 to 255
This feature is not available with the D7212GV3.
Keep the default setting.
U### Mstr Crd Data
Default: Blank
Selection: 00000 = (0) to 65534 or Blank
(65535)
This feature is not available with the D7212GV3.
Keep the default setting.
U### SU1 through SU3 Site
Default: 255
Selection: 0 to 255
This feature is not available with the D7212GV3.
Keep the default setting.
U### SU1 through SU3 C/D
Default: Blank
Selection: 00000 = (0) to 65534 or Blank
(65535)
This feature is not available with the D7212GV3.
Keep the default setting.