D7212GV3 | Program Entry Guide | 5.0 Schedules (Skeds) EN | 98
Bosch Security Systems, Inc. | 10/11 | F01U170808-02
W# Close Early Begin
Default: 00: 00
Selection: HH:MM (hours and minutes)
00:00 to 23:59
Close Early Begin: This program item is one of
three required to create a Closing Window. To finish
programming a Closing Window, Close Window Start
and Close Window Stop must be programmed.
The time programmed in the Close Early Begin field
is the earliest time the user can close an area before
the Closing Window Start time. If Opening and
Closing Reports are enabled, arming the area
between midnight and the Close Early Begin time
generates a Closing Report. Additionally:
If A# Disable O/C in Window is set to Yes
and the area is armed between the Close
Early Begin time and the Close Window Start
time, the Closing Event is sent with an Early
to Close modifier. If the Close Early Begin
time is the same as the Close Window Start
time, no Closing Event is sent.
If A# Disable O/C in Window is set to No
and the area is armed at any time, a Closing
Event is sent without the Early to Close or
late to Close modifiers.
Arming the area between the Close Window Start
and Close Window Stop times creates a local event
in the control panel event log, but does not send the
Closing Report to the central station.
Arming the area after the Close Window Stop time
and before the next window’s Close Early Begin time
(or midnight, whichever is earlier) generates a
Closing Event with a Late to Close modifier.
When configuring multiple windows to operate on the
same day, ensure that they are added to the system
in chronological order. For example, if three windows
are programmed to execute on Tuesday, Window 1
(W1) must occur before Window 2 (W2), and Window
2 must occur before Window 3 (W3).
Avoid programming the Open Early Begin
time before a time that is between another
window’s Open Window Start and Open
Window Stop times.
Disabled windows have a beginning time of 00:00. If
the entry for this prompt is 00:00, but times are
programmed for Close Window Start and Close
Window Stop, the window is disabled.
To disable the window, both the hours and minutes
spaces must be 00:00.
00:00 is midnight, 23:59 is 11:59 PM. Make entries
using a 24-hour clock (for example, 7:00 AM is
entered as 07:00, 2:45 PM is entered as 14:45).
Reboot the control panel to activate today’s window.
The window needs to activate on the same day you
program it.
W# Close Window Start
Default: 00: 00
Selection: HH:MM (hours and minutes)
Enter the time that you want the control panel to start
the Closing Window. The window goes into effect at
the beginning of the minute.
00:00 is midnight, 23:59 is 11:59 PM. Make entries
using a 24-hour clock (for example, 7:00 AM is
entered as 07:00, 2:45 PM is entered as 14:45).
This program item is one of three required to create a
Closing Window. To program a Closing Window,
Close Early Begin and Close Window Stop must also
be programmed.
If the area is not armed when the Close Window Start
time comes, a warning tone sounds and PLEASE
CLOSE NOW appears at the keypad. To temporarily
silence the tone, press the [ESC] key on the keypad.
The warning tone restarts in 10 min if the area is not
armed.
Refer to the W# Close Early Begin prompt in this
section for explanations of report features.
W# Close Window Stop
Default: 00: 00
Selection: HH:MM (hours and minutes)
Enter the time that you want the control panel to end
the Closing Window. The window stops at the end of
the minute.
00:00 is midnight, 23:59 is 11:59 PM. Make entries
using a 24-hour clock (for example, 7:00 AM is
entered as 07:00, 2:45 PM is entered as 14:45).
This program item is one of three required to create a
Closing Window. To program a Closing Window,
Close Early Begin and Close Window Start must also
be programmed.
If the area is not armed by the time the Close
Window Stop time expires, the control panel
generates a Fail to Close Report if enabled in Fail To
Close.
Closing Reports generated between the Close
Window Start time and Close Window Stop time can
be suppressed by programming Disable O/C in
Window as Yes. Refer to the W# Close Early Begin
prompt for other explanations of report features.