EasyManua.ls Logo

Bosch D7412GV2 - Page 83

Bosch D7412GV2
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D9412GV2/D7412GV2 | Troubleshooting Guide | 3.0 Troubleshooting
.
Bosch Security Systems, Inc. | 11/05 | F01U011024B 83
8. Set the Enable Enhanced Communication?
prompt to Yes and enter the IP address of the
D6600 Receiver for Path 1 IP Address.
3.4.1 Programming the Control Panel for Network
Communication
Using RPS (RAM IV)
1. Using RPS, receive the control panel’s
programming. For more information, refer to
Section
4.3.1 Receiving Control Panel Programming
Using RPS
on page 124.
2. Using RPS, go into Gv2MAINPanel Wide
ParametersRouting.
9. Select the Path 1 Poll Rate parameter. (For UL
requirements, refer to the DX4020 Installation Guide
[P/N: 49522]).
3. Set the Primary on Route Group 1 prompt to 1.
10. Using RPS, select D9412V2 Program Record
SheetGV2AUXMisc.
11. Under the Misc prompt, select Enable Anti
Replay and select Yes for the value.
4. Using RPS, go into GV2MAINPanel Wide
ParametersEnhanced Routing.
12. Send the programming data to the control panel.
For more information, refer to Section
4.3.2 Sending
Programming Changes to the Control Panel Using RPS
5. Set the Route Group 1 Primary SDI prompt to
Yes.
on page
124.
13. Reboot the control panel to synchronize the
numeric keys.
6. Exit from GV2MAINPanel Wide Parameters
and select GV2AUX.
7. Click the small plus symbol and select Enhanced
Communications.

Table of Contents

Other manuals for Bosch D7412GV2