22 en | Reporting Format Definitions D9412GV3/D7412GV3/D7212GV3
F01U170805 | 01 | 2010.11 Quick Reference Guide Bosch Security Systems, Inc.
Force Armed Perimeter
Instant
Csiii Nria/idiiiNF Partial Arm 3 456 aa uuu
Forced Close Early by
Area
Csiii Nria/idiiiCF Early O/C 3 451 aa uuu
Forced Close Late by Area Csiii Nria/idiiiCF Late O/C 3 452 aa uuu
Forced Closing by Area Csiii Nria/idiiiCF O/C by user 3 401 aa uuu
Forced Point Tsppp NriaXWppp Zone/Sensor Bypass 1 570 aa ppp
Invalid local access
detected
TsF01 NLU Unsuccessful access 1 413 00 000
Low battery on a wireless
point
Tsppp NriaXTppp RF Low Battery 1 384 aa ppp
Low battery restore on a
wireless point
Rsppp NriaXRppp RF Low Battery 3 384 aa ppp
Missing Alarm Msppp NriaUZppp General Alarm 1 140 aa ppp
Missing Fire Supervision GMsppp NriaFZppp Fire Trouble 1 373 aa ppp
Missing Supervision MTsppp NriaBZppp Loss of Supervision - RPM 1 382 aa ppp
Missing Trouble Vsppp NriaUYppp Loss of Supervision - RPM 1 382 aa ppp
Non- Fire Cancel Alarm \siii Nria/idiiiBC Cancel 1 406 aa ppp
Normal start-up of the
control panel
NsD14 NRR System Reset 1 305 00 000
Opening by Area Osiii Nria/idiiiOP O/C by user 1 401 aa uuu
Opening Early by Area Osiii Nria/idiiiOK Early O/C 1 451 aa uuu
Opening Late by Area Osiii Nria/idiiiOJ Late O/C 1 452 aa uuu
Parameters changed by
RPS
NsD02 NYG Panel Programming Changed 1 306 00 000
Phone Line Missing (1 or
2)
TsssB NLT1 or NLT2 Telco 1 Fault 1 351[5] 00 000
Phone Line Restored (1 or
2)
RsssB NLR1 or NLR2 Telco 1 Fault 3 3515 00 000
Point Bus Fail TsssD NET Protection Loop 1 370 00 000
Point Bus Restoral, power
normal or bus not missing
RsssD NER Protection Loop 1 370 00 000
RAM Fail with RPS TsF02 NRA Unsuccessful access 1 413 00 000
Relay Reset by
Programmer
NsD22 NpidddROrrr Sounder/Relay 3 320 00 000
Relay Reset by Remote NsD24 NROrrr Sounder/Relay 3 320 00 000
Relay Reset by Sked NsD20 NaikkkROrrr Sounder/Relay 3 320 00 000
Relay Reset by User NsD18 NidiiiROrrr Sounder/Relay 3 320 00 000
Relay Set by Programmer NsD21 NpidddRCrrr Sounder/Relay 1 320 00 000
Relay Set by Remote NsD23 NRCrrr Sounder/Relay 1 320 00 000
Relay Set by Sked NsD19 NaikkkRCrrr Sounder/Relay 1 320 00 000
Relay Set by User NsD28 NidiiiRCrrr Sounder/Relay 1 320 00 000
Remote Reset – System
was reset by RPS
NsD11 NRN System Reset 1 305 00 000
Restoral Rsppp NriaBRppp Sensor Trouble 3 380 aa ppp
Restoral from Alarm Rsppp NriaBHppp Burglary 3 130[3] aa ppp
Restoral from Ground
Fault
Rsppp NriaBRppp Ground Fault 3 310 aa ppp
ROM Checksum Fail (Not
Used)
AsD12 NYX ROM Checksum bad 1 304 00 000
Sensor Reset NsD27 Nria/idiiiXIrrr Sounder/Relay 3 320 00 000
Service Walk Test End RsssF NidiiiTE Service On/Off Premises 3 466 aa uuu
Modem IIIa
2
Event Modem IIIa
2
Code
D6500 Mode
Modem IIIa
2
Code
Bosch SIA Mode
Contact ID Event Contact ID
Code