D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 4.0 Installation
.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09 26
4.11.5 IP Diagnostics
With at least one B420 Ethernet Communication
Module, or B426 Ethernet Communication
Module installed on the SDI2 bus, the control
panels can use the diagnostic functions of this
menu to retrieve the auto-configured settings
from the module and perform a series of network
communication tests. This menu does not apply
to the DX4020 modules on the SDI bus.
The Settings option retrieves the following from
the selected B420 module: Unit Host Name, MAC
ID, and current IPV4 Address. For the B426
module, the Settings option retrieves: Unit Host
Name, MAC ID, and current IPv6 Address.
The Connection Test option performs the
following automated tests for the selected
B426/B420 module:
Link [OK] if Ethernet cable is detected
[Missing] if Ethernet cable is not detected.
Gateway [OK] if an ICMP echo request (PING)
response is received from the Gateway
Address. [Failure] if response is not
received.
Internet [OK] if an ICMP echo request (PING)
response is received from the IP Test
Address. [Failure] if response is not
received.
Refer to the Control Panels
(D9412GV4/D7412GV4 v2.03) Program Entry
Guide (P/N: F01U265459) for details on the
B426/B420 Ethernet Communication Module
configuration.