D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 111
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
L## Remote Program
Start a remote programming software (RPS) session when the phone rings at the control
panel.
L## Move to Area
Temporarily switch to a different area and perform keypad functions related to that area.
L## Display Rev
Display the control panel model name and software revision. For example:
9412GV4 REV ##.##
L## Service Walk
Start a Service Walk Test for all 24-hour Interior or Perimeter Controlled points in the control
panel.
Points are not included in this test if:
Points are in an area that is already in a Walk Test Mode.
Points are assigned to an area that is not enabled A# Area On.
Points are in an area that is Master or Perimeter armed.
Point source is Unassigned and the Point Index is set to 0.
When a Service Walk Test is initiated, one person can test all the points in the control panel
without assistance. The following features are provided with the Service Test Mode:
Display indicates exactly how many points can be tested.
Battery and bell tests do not occur during this Walk Test.
The test ends when all points are tested or the test times out after 20 min of inactivity.
Events print locally without alarm annunciation or reporting to the central station
receiver.
D1255 Keypad displays a sequential count and the text for the point after each point is
activated and restored.
The D1255 Keypad displays ALL PNTS TESTED.
If enabled in Routing, Service Start and Service End are reported at the central station
receiver for the beginning and end of the test.
Default: Authority Levels 1-4, 15: Enabled (E)Authority Levels 5-14: Blank (-)
Selection: - or E
Function No. Function Name Alternate Keystroke
29 Remote Programming [COMMAND][4][3]
Default: Authority Levels 1-2, 15: Enabled (E)Authority Levels 3-14: Blank (-)
Selection: - or E
Function No. Function Name Alternate Keystroke
30 Move to Area [COMMAND][5][0]
Default: Authority Levels 1, 15: Enabled (E)Authority Levels 2-14: Blank (-)
Selection: - or E
Function No. Function Name Alternate Keystroke
32 Display Software
Revision
[COMMAND][5][9]
Default: Authority Levels 1, 15: Enabled (E)Authority Levels 2-14: Blank (-)
Selection: - or E
Function No. Function Name Alternate Keystroke
33 Service Walk test (Menu function only)