4 Unbypass a Point: This function emulates the
Unbypass Pt? keypad function. The entry in
the S## Point Number prompt defines the
point this sked unbypasses. The sked can
unbypass one point.
S## Point Number
Default: Blank
Selections: Blank, 1 to 127,
129 to 247 for D9412GV4,
1 to 75 for D7412GV4, 1 to
40 for D7212GV4
Enter the number of the
point the sked unbypasses.
Blank (0)
1 to 127,
129 to 247
No point is
unbypassed.
Point to unbypass.
5 Unbypass All Points: This function is not
available as a keypad function. The entry in
the S## Area # prompt defines the area(s)
where the sked unbypasses all points. The
sked unbypasses all points in the area,
regardless of how they were bypassed. This
sked can unbypass all points in multiple areas.
S## Area 1[through #]
Default: No
Selection: Yes or No
Select Yes to unbypass all
points in the areas
indicated.
Yes
No
Unbypass all
points in Area #.
Do not unbypass
all points in Area
#.
6 Relay On: This function emulates the Change
Relay keypad function to turn relays on. The
entry in the S## Relay Number prompt
defines the specific relay this sked activates.
The sked can activate one relay.
S## Relay Number
Default: Blank
Selections: Blank, 1 to 128
for D9412GV4, 1 to 64 for
D7412GV4, 1 to 24 for
D7212GV4
Enter the number of the
relay the sked activates
Blank
1 to 128
No relay is
activated.
Relay to activate.
7 Relay Off: This function emulates the Change
Relay? keypad function to turn relays off. The
entry in the S## Relay Number prompt
defines the relay this sked turns off. The sked
can turn off only relays that are set by a sked.
The sked can turn off one relay.
S## Relay Number
Default: Blank
Selections: Blank, 1 to 128
for D9412GV4, 1 to 64 for
D7412GV4, 1 to 24 for
D7212GV4
Enter the number of the
relay that turns the sked off.
Blank
1 to 128
No relay is turned
off.
Relay to turn off.
8 All Relays Off: This function is not available as a keypad function. This sked function turns off all relays that
are turned on by a sked. This is a panel-wide function.
No other parameters require input for this option.