D9412GV4/D7412GV4/D7212GV4 Schedules (Skeds) | en 169
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
14 Adjust Time Backward One Hour: This sked function is used to make adjustments to the control panel’s clock.
A typical application is to program this to go into effect at 2:00 AM on the date that Daylight Saving Time ends
(during the fall). This function can operate only once in a day, even if multiple Skeds with this function are
programmed. No Time Change Report is sent or logged, but the new time appears in the next report logged.
There are no other parameters that require input for this option.
15 Sound Watch Tone at Command Center
(Keypad): This function sounds the Watch
Tone at the keypad address programmed
in Parameter 1. The Watch Tone sounds at
all keypads with the address programmed.
Press [ESC] to silence the tone.
Sound Watch Tone defines the keypad
address where the Watch Tone sounds.
Enter the specific address at the S## Cmd
Center prompt.
S## Cmd Center 1
[through 16]
Default: Blank
Selections: Yes or No
Enable the sked to beep
the keypad programmed
Yes.
Yes
No
Watch tone sounds at
this keypad.
Watch tone does not
sound at this keypad.
16 Access Control Level On: (D9412GV4 and
D7412GV4) This function emulates the
ACCESS CMD LEVEL command that
determines whether a user’s token or card
level is ENABLED?, allowing access
granted rights. This affects all doors that
this user is assigned to with this specific
authority level.
S## Access Ctl Level #
Default: No
Selection: Yes or No
Activate a sked, which
enables the Access
Level(s) 1 through 14
with Yes.
Yes
No
Enable Access Control
for indicated authority
levels.
Do not enable Access
Control for indicated
authority levels.
NOTICE!
The D9412GV4 supports eight doors; the D7412GV4 supports two doors.
NOTICE!
To regulate a user’s access for certain doors, assign the user a different authority level # with
the same authority functions enabled. For example, a user can be assigned Authority Level 1
for Door 1 and Authority Level 2 for the remaining doors. You can enable or disable Authority
Level 1 for Door 1 without affecting his authority level for Doors 2 through 8).
Default: 0
Selection: 0 to 24, 28, 29
17 Access Control Level Off: (D9412GV4 and
D7412GV4) This function emulates the
ACCESS CMD LEVEL command that
determines whether a user’s token or card
level is disabled. This function allows access
to be turned off for the levels programmed.
S## Access Ctl Level #
Default: No
Selections: Yes or No
Enables the sked to
turn off access for
Levels 1 through 14.
Yes
No
Turn off access for
indicated authority
levels.
Do not turn off access for
indicated authority
levels.
18 Unlock Door: (D9412GV4 and D7412GV4)
This function emulates the UNLOCK?
12345678 keypad function for unlocking a
door.
S## Door 1 [through 8]
Default: No
Selection: Yes or No
Enable the sked to
unlock the doors
programmed Yes.
Yes
No
Unlock Door #.