D9412GV4/D7412GV4/D7212GV4 ACCESS CONTROL (D9412GV4/D7412GV4) | en 195
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
9 ACCESS CONTROL (D9412GV4/D7412GV4)
This section applies only to the D9412GV4 and D7412GV4 Control Panels.
9.1 Door Profile
This programming category is used to:
– Assign an area that also activates the D9210C
– Assign a point to the door
– Program the door state to change the time when the arm state changes
– Allow for the Strike relay to activate upon a fire alarm
– Programming the Interlock point
Door Number
D# Entry Area #
Assign an area to the door controller. This entry allows the D9210C to be polled, activating
communication to the control panel. This is also the area a user exits when initiating a REX.
D# CC# Scope
NOTICE!
The D9412GV4 supports up to eight doors. The D7412GV4 supports two doors.
Default: Disabled
Selection: Disabled, 1 to 32
1 to 32 The area assigned to the door controller to which the reader allows
access.
Disabled Door controller does not function.
NOTICE!
The D# Entry Area # prompt for the D7412GV4 is limited to the first 8 areas.
NOTICE!
All SDI devices, regardless of area assigned, report to Area 1, Account 1 by default upon SDI
failure. If a D9210C becomes disconnected, an SDI Fail ## and a Missing Point ### Event is
created.
NOTICE!
If the D9210C is not programmed with a D# Entry Area, 9210 NOT READY appears at the
keypad when attempting to add access credentials to a User ID.
Default: 1
Selection: Disabled, 1 to 16 (for D9412GV4), 1 to 8 (for D7412GV4)
1 to 16 Determines the scope of areas to affect the access disarm request if
enabled. Also, determines the keypad to be used when performing Dual
Authentication.
Disabled Only the area assigned in D# Entry Area is disarmed if the user has
access disarm rights. No keypad assignment prohibits Dual
Authentication.