20 en | Panel and Area Wide Parameters D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
This program item determines how point and User ID numbers are presented at the D6500 or
D6600 display, printer, and computer RS-232 output.
When Phone # Format is ModemIIIa
2
, the control panel sends expanded Bosch ModemIIIa
2
Communication Format reports to the D6500 or D6600. If your central station data files are
not set up for point and User ID number reporting, you can use this program item to convert
these numbers to COMEX Reports.
When Phone # Format is ModemIIIa
2
, the control panel sends expanded Bosch ModemIIIa
2
Communication Format Reports to the receiver. Point/User Flag affects Bosch ModemIIIa
2
Communication Format data as shown in Table 3.1, Page 20. The Bosch Security Systems, Inc.
D6500 or D6600 Receiver adds the leading zero in the User ID number with Point/User Flag
programmed No.
Table 3.1 ModemIIIa2 Communication Format Data - User ID Numbers
Yes The control panel sends a flag with each report telling the D6500 or
D6600 to convert point numbers and User ID numbers to COMEX
format. Refer to Table 3.1, Page 20 and Table 3.2, Page 21 for
conversion information. When this parameter is programmed Yes,
points and User ID numbers are converted, regardless of the
programming of the D6500 or D6600 Receiver for output to the
computer system. Refer to Appendix C in the Conettix D6600/D6100
Receiver/Gateway Computer Interface Manual (P/N: 4998122703).
No The control panel does not send the flag. The D6500 or D6600 outputs
point numbers as 001 to 247 (rather than 100 to 732) and User ID
numbers as 000 to 999 (rather than 000 to F08), as indicated in
Table 3.1, Page 20 and Table 3.2, Page 21.
Point/User Flag No Point/User Flag Yes
001 to 005 001 to 005
006 to 013 601 to 608
014 to 021 701 to 708
022 to 029 801 to 808
030 to 037 B01 to B08
038 to 045 C01 to C08
046 to 053 D01 to D08
054 to 061 E01 to E08
062 to 069 F01 to F08
070 to 999 000