D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 73
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
A# Fail to Close
This item determines if a Fail to Close Report is sent for this area. Use to determine if a user
failed to arm the area before the Closing Window expires. Normal Opening and Closing
Reports do not need to be programmed to use this feature.
A# Latest Close Time
Use to set a Latest Close Time boundary value for this area. If the Latest Close Time value is
non-zero, the time of day specified with the Extend Close feature cannot be greater than or
equal to this value. A zero value for A# Latest Close Time disables the feature for the area.
Example: If A# Latest Close Time is set for 17:30, the user can extend the close time to as late
as 17:29.
This prompt is used only when an O/C Window is assigned to an area. Make entries in 30-min
increments using a 24-hour format. Use times that begin on the hour or the half-hour only. For
example, enter 2:30 PM as 14:30. Enter 1:00 AM as 01:00. To set the Latest Close Time for
midnight, use a value of 24:00. The latest close time allowed by the Extend Close feature is
24:58, because of internal limitations in the control panel.
The control panel sets all windows for the next day when the control panel clock turns to
midnight. The control panel must cross the midnight boundary before any changes in that
default setting occur.
To extend across midnight, you must use two windows:
– To suppress reports before midnight, use one window (for example, 20:00 start to 23:59
stop).
– To suppress reports immediately after midnight, use another window (for example, 00:01
start to 02:00 stop).
Default: No
Selection: Yes or No
Yes Fail to Close Report is sent for this area if the area is not armed when
the Closing Window stop time occurs.
Note:
Program an exit delay time in Exit Dly Time.
No Fail to Close Report is not sent for this area.
–If Auto Close is programmed Yes, a Fail to Close Report is sent
because it occurs when the Closing Window stop time occurred.
–If Disable O/C in Window is Yes, the Fail to Close Report is
followed by Closing Late or Force) Close Late.
Default: 00:00
Selection: 00:00 to 24:00
NOTICE!
The default entry of 00:00 disables the Latest Close Time feature for this area.