D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 75
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
Use this parameter when disarming an area that is Master Armed. After recognizing the first
valid passcode, the system requests a second passcode to disarm the area. If the entry delay
expires before the entry of a second valid unique passcode, an alarm condition occurs. This
function works only when you use Passcode Disarm.
Parameter Setup Requirements:
Two Man Rule can be completed only by entering two valid unique passcodes with L##
Passcode Disarm authority.
D1255 Keypad
After the first valid passcode is entered, the D1255 replaces the scrolling DISARM NOW and
the Point Text display with the SECOND CODE:.display
When the user presses the first digit of the second code, the display changes to SECOND
CODE: *.
SECOND CODE: appears for 19 sec. If no digits are pressed, the display returns to normal and
the area does not disarm. If a second code is entered, the area disarms and an Opening report
is sent with the User ID of the first user. If the second code entered is the same as the first
code, is invalid, or does not have L## Disarm authority, the keypad shows NO AUTHORITY and
returns to idle text or entry delay.
D1260 Keypad
NOTICE!
The D720 Keypad does not support the Two-Man Rule feature.
NOTICE!
When you are disarming an area with A# Two Man Rule set to Yes, the keypad waits for the
time equal to the A# Exit Delay Time. If the second passcode is not entered before the
prompt times out, the rule resets and waits for the first passcode again.
NOTICE!
If the area is already in an alarm condition, the first valid passcode entered after the alarm
occurs silences the bell but does not disarm the area. Enter Code 2 appears on the display. A
second valid unique passcode is necessary to disarm the area.
NOTICE!
This feature is not allowed for use with SIA CP-01 compliant installations. Consult the local
authority having jurisdiction (AHJ) for proper usage. Refer to your control panel’s program
entry guide for programming information.
NOTICE!
To avoid unintended results for the end user of the system:
–Set CC# Scope to Area Wide for keypads assigned to areas with the Two Man Rule
feature.
Avoid setting the A# Two Man Rule to Yes in an area where A# Early Ambush is set to
Yes.
NOTICE!
Use this feature in banks or other facilities that might require a higher level of security to gain
access to a vault or other protected area.