78 en | Panel and Area Wide Parameters D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
For SIA CP-01 Compliance
This prompt can be set to Yes or No.
A# Arm No Exit
This parameter switches the arming state of an area from Master Armed to Perimeter Armed if
no perimeter points with delay response were activated during the exit delay time. Only the
final armed state is reported and displayed at the keypads.
For SIA CP-01 Compliance
This prompt can be set to Yes or No.
A# Exit Warning
When enabled, the Alarm Bell output pulses on and off every 2 sec for the remaining 10 sec of
the Exit Delay time.
For SIA CP-01 Compliance
A# Exit Warning must be set to Yes.
A# Entry Warning
When enabled, the Alarm Bell output pulses on and off every 2 sec for the remaining 10 sec of
the Entry Delay time.
For SIA CP-01 Compliance
A# Entry Warning must be set to Yes.
3.11 Keypad (Command Center)
This programming module contains three programming categories: Command Center
Assignments, Area Text, and Custom Function.
Default: No
Selection: Yes or No
Yes Switch the arming state to Perimeter if no Perimeter Delay point faults
occurred.
No Keep the area in Master Arm if no Perimeter Delay point faults
occurred.
NOTICE!
The A# Arm No Exit feature does not operate in areas with A# Area Type set to Shared.
Default: No
Selection: Yes or No
Yes Pulse the alarm output for the last 10 sec of the Exit Delay time.
No Do not pulse the Alarm Bell out during the Exit Delay time.
NOTICE!
The A# Arm No Exit feature does not operate in areas with A# Area Type set to Shared.
Default: No
Selection: Yes or No
Yes Pulse the alarm output for the last 10 sec of the Entry Delay time.
No Do not pulse the Alarm Bell output during the Entry Delay time.