EasyManua.ls Logo

Bosch D7412GV4 - Add User

Bosch D7412GV4
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
88 en | Panel and Area Wide Parameters D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
CC# Abort Display can be set to Yes or No.
CC# Cancel Display
This parameter enables or disables the CANCEL REPORT SENT display message when an
alarm is canceled after transmission occurs. To show this message, Cancel Report must be
set to Yes. Refer to Section 3.9 Miscellaneous, page 59.
For SIA CP-01 Compliance
CC# Cancel Display can be set to Yes or No.
3.11.2 Area Text
Use this programming category to create custom Idle Text displays for the keypads.
Area# Is On
Enter the text for this area that appears when the area is master armed or master instant
armed and other areas sharing the same account number are not yet master armed. This
display does not appear when the area is perimeter armed.
Area# Not Ready
Enter the text for this area that displays when the area is disarmed but points are faulted.
Area# Is Off
Enter the text for this area that displays when the area is disarmed an no points are faulted.
Area# Account is On
Enter the text that appears when all areas sharing the same account number are master
armed. The ACCOUNT IS ON text appears at all keypads assigned to these areas, if more than
one area has the same account number. The ACCOUNT IS ON text also appears if only one
area in the system is used. Refer to the prompts CC# Area Assign and Area # Account Is On
in Section 3.11.1 Keypad (Command Center) Assignment, page 79. When all areas in the
account are master armed, the Area # Is On text is replaced by the ACCOUNT IS ON text if the
area is armed before all other areas with the same account number.
Blank Entry
Default: Yes
Selection: Yes or No
Yes This keypad shows the Cancel Report Sent message for all canceled
alarms within its scope.
No This keypad does not show the Cancel Report Sent message for all
canceled alarms within its scope.
NOTICE!
Each display can be programmed with up to sixteen alphanumeric characters, including: A to
Z, 0 to 9, ?, &, @, -, *, +, $, #, _, /.
Characters not listed are invalid and cannot be used for text.
Default: Refer to the program record sheet
Selection: Sixteen alphanumeric characters
Default: Refer to the program record sheet
Selection: Sixteen alphanumeric characters
Default: Refer to the program record sheet
Selection: Sixteen alphanumeric characters
Default: Refer to the program record sheet
Selection: Sixteen alphanumeric characters

Table of Contents