EasyManua.ls Logo

Bosch D9412G - Cross Point Time

Bosch D9412G
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1 EN | 129
Bosch Security Systems | 10/03 | 47775E
Conversely, if a single Cross Point detects an alarm,
then restores, and no other conditions occur, an
Unverified Event is generated for that point. A
second alarm on the first point does not create an
Alarm Event but rather an Unverified Event.
Section 2.3 Routing determines whether these events
are transmitted to a central station. An Unverified
Event does not produce a corresponding Restoral
Event.
The Cross Point function applies only to alarm
conditions. It does not apply to supervisory or
trouble conditions. Points programmed with point
response D (Delayed) eventually go into an alarm
condition if the area is not disarmed in time.
Use the Cross Point function on Non-fire
points only.
Cross Point Time
Default: 20 seconds
Selection: 5 seconds to 255 seconds
Select the amount of time (in seconds) that points
within a Cross Point Group are in alarm before a
Cross Point event is generated.

Table of Contents

Other manuals for Bosch D9412G

Related product manuals