D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN EN | 38
Bosch Security Systems | 10/03 | 47775E
A# Duress Enable
Default: No
Selection:
Yes or No
Yes Enable Duress alarm for this area.
No Disable Duress alarm for this area.
This entry determines if this area allows duress
alarms to be generated. See the
Duress Type
prompt
in Section 2.8 Miscellaneous for an
explanation of duress.
Setting this item to No for a particular area
and entering a valid duress passcode for
that area at the command center now
displays NO AUTHORITY.