EasyManua.ls Logo

Bosch D9412GV2 - TTP31: SDI Fail 1 to 8; TTP32: Silencing Alarms or Troubles, and Clearing Keypad Memory

Bosch D9412GV2
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D9412GV2/D7412GV2 | Troubleshooting Guide | 3.0 Troubleshooting
70 Bosch Security Systems, Inc. | 11/05 | F01U011024B
TTP31: SDI Fail 1 to 8 TTP32: Silencing Alarms or Troubles, and
Clearing Keypad Memory
This error message appears at the central
station. The keypad at the site shows
SERVICE KEYPAD.
D1255 Keypad Procedures
If using a D1255 keypad that is sounding an alarm:
1. Press [Passcode][ENT] to silence the alarm.
Procedure
2. Press [Passcode][ENT] again to disarm the system.
Refer to
TTP30 Keypad Shows SERVICE KEYPAD on
page
3. Press [Passcode][MENU/ESC] to clear keypad
memory.
69.
4. If the point is still in an alarm condition, it shows
as faulted on the keypad. Press [NEXT] to view the
point.
If using a D1255 keypad that is sounding a trouble:
1. Press [COMMAND][4] to silence the trouble.
2. Points in trouble now appear as faulted points.
Press [NEXT] to view the points.
D1260 Keypad Procedures
If using a D1260 keypad that is sounding an alarm:
1. Press [Passcode][ENTER] to silence the alarm.
2. Press [Passcode][ENT] again to disarm the system.
3. Press [Clear display][Passcode][Clear] to clear
keypad memory.
4. If the point in alarm was a controlled point, it
appears as faulted on the keypad. Press [NEXT] to
view the point.
If the point in alarm was a 24-hour point, press
any numeric key. The keypad shows the points
that are in an alarm state.
If using a D1260 keypad that is sounding a trouble:
1. Press [Silence] to silence the alarm.
2. Press any numeric key. The keypad shows the
points that are in a trouble state.

Table of Contents