D9412GV2/D7412GV2 | Troubleshooting Guide | 3.0 Troubleshooting
84 Bosch Security Systems, Inc. | 11/05 | F01U011024B
E
Using a D5200 Programmer
For more information, refer to D5200 Programmer’s
Operation and Installation Guide (P/N: 74-06176-000).
1. Using your D5200 Programmer, receive data
from the control panel. Refer to Section
4.3.3
Receiving Control Panel Programming Using the
D5200 Programmer
on page 125.
2.
Select
PANEL WIDE PARAMETERS and press
[ENTER GROUP].
3.
Select
Routing and press [ENTER GROUP].
4.
In Routing, select R1 Primary Device 1 and
press [1] to set the value to 1.
Press [ENTER] to accept the value
5.
Press [EXIT GROUP] once to return to PANEL
WIDE PARAMETER.
6.
Select
Enhanced Routing and press [ENTER
GROUP].
7.
Set RG1 Primary SDI to
Yes and press
[ENTER].
8. Send the new record to the control panel. Refer to
Section
4.3.4 Sending Programming Changes to the
Control Panel Using the D5200 Programmer
on page
125.
You can press [SEND (LOAD)] on the
D5200 Programmer at any time.
9. Receive a copy of GV2AUX from the control
panel. Refer to Section
4.3.3 Receiving Control Panel
Programming Using the D5200 Programmer
on page
125.
10.
Select
NHANCED COMM and press [ENTER
GROUP].
Set ENHANCED COMM to Yes by pressing [Y].
Press [ENTER].
11.
12. Enter the IP address of the D6600 Receiver in
Path 1 IP Add1 to Path 1 IP Add 4 by pressing
the number keys and [ENTER] after each octet of
the IP address.
Select Path 1Poll Rate and set it to 75, then press
[ENTER].
13.
14. Press [EXIT GROUP] to exit from ENHANCED
COMM.
At the NEWRECORD menu, press [] repeatedly
to scroll down to
15.
MISCELLANEOUS and press
[ENTER GROUP].
E
16.
Set
nableAntireplay to Yes by pressing the [Y]
key. Press [ENTER].
17. Send the new record to the control panel. Refer
to Section
4.3.4 Sending Programming Changes to the
Control Panel Using the D5200 Programmer
on page
125.