To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D9412GV2/D7412GV2 | Program Entry Guide | 7.0 RADXAXS EN | 140
Bosch Security Systems | 5/05 | F001U003636B
D# Access Granted?
Default: No
Selection: Yes or No
Yes
Access Events from this door
controller are sent to the control
panel for processing.
No
Access Events from this door
controller are not sent to the control
panel for processing.
This program item determines if Access Granted and
Door Request Events are sent to the control panel for
processing memory, printing, and remote reporting.
A successful Access Event can be startd
by a(n):
Valid user ID
Valid door state changed at the
keypad.
Automatically scheduled or armed state
change that holds a door open
RTE or REX.
D# No Entry?
Default: No
Selection: Yes or No
Yes
Access Denied Events from this door
controller are sent to the control
panel for processing.
No
Access Denied Events from this door
controller are not sent to the control
panel for processing.
This program item determines if No Entry Events are
sent to the control panel for processing memory,
printing, and remote reporting.
A No Entry Event can be caused by:
Invalid or unknown user ID, interlock or
secured door, or incorrect authority
level
RTE or REX for door in interlock or
secured door.
D# Enter Request?
Default: No
Selection: Yes or No
Yes
A Door RTE Event from this door
controller is sent to the control panel
for processing.
No
A Door RTE Event from this door
controller is not sent to the control
panel for processing.
This program item determines if RTE Events are sent
to the control panel for processing memory, printing,
and remote reporting.
RTE Events require D# Access Granted to
be programmed as Yes.
D# Exit Request?
Default: No
Selection: Yes or No
Yes
A Door RTE Event from this door
controller is sent to the control panel
for processing.
No
A Door RTE Event from this door
controller is not sent to the control
panel for processing.
This program item determines if REX Events are sent
to the control panel for processing memory, printing,
and remote reporting.
REX Events require D# Access Granted
to be programmed as Yes.