EasyManua.ls Logo

Bosch D9412GV4 - Page 118

Bosch D9412GV4
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 18.0 Installer Menu
.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09 118
4. Delete existing characters, if necessary, and then enter the new number. Use [PREV] or [NEXT]
to move to a different byte.
5. When finished, press [ENTER] to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads Configuration of IPv4 Server Address
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [2] Network > [1] Bus Module (1) or [2] Bus Module (2) > [3] DNS Parameter >
[1] IPv4 Server Address menu option. The keypad displays the IPv4 Server Address current
configuration.
3. Press the IPv4 Server Address softkey to edit the IP address.
4. Delete existing characters, if necessary, and then enter the new number. Use /[PREV] or
/[NEXT] to move through the different bytes.
5. Press the Save softkey to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
IPv6 Server Address
B91x/B92x keypads Configuration of IPv6 Server Address
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [2] Network > [1] Bus Module (1) or [2] Bus Module (2) > [3] DNS Parameter >
[2] IPv6 Server Address menu option. The keypad displays the IPv6 Server Address current
configuration.
3. Press [ENTER] to edit the IPv6 Server Address.
4. Delete existing characters, if necessary, and then enter the new number. Use [PREV] or [NEXT]
to move to a different byte.
5. When finished, press [ENTER] to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads Configuration of IPv6 Server Address
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [2] Network > [1] Bus Module (1) or [2] Bus Module (2) > [3] DNS Parameter >
[2] IPv6 Server Address menu option.
3. Press the IPv6 Server Address softkey to edit the IP address.
4. Delete existing characters, if necessary, and then enter the new number. Use /[PREV] or
/[NEXT] to move through the different bytes.
5. When finished, press the Save softkey to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
Module Hostname
B91x/B92x keypads Configuration of Module Hostname
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [2] Network > [1] Bus Module (1) or [2] Bus Module (2) > [3] DNS Parameter >
[3] Module Hostname menu option.
3. Press [ENTER] to edit the hostname.
4. Delete
existing characters, if necessary, and then enter the new characters.
5. When finished, press [ENTER] to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.

Table of Contents

Other manuals for Bosch D9412GV4

Related product manuals