EasyManua.ls Logo

Bosch D9412GV4 - Page 176

Bosch D9412GV4
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
176 en | AUXPARM D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
Early Ambush Timer
The programmed time is the maximum value of the Early Ambush Timer. When Early Ambush
is set to Yes for a specified area (refer to Section Early Ambush, page 76) and the area is
disarmed, the user has the amount of time programmed here to enter a second code into the
keypad.
If a second passcode is not entered within the programmed time, a Duress event is generated
based on the first user code. Duress reports must be enabled in Routing in order to be sent to
a central station.
Fire Trouble Resound
Secondary Ambush Code
The Secondary Ambush Code determines whether the same passcode can be used to begin
and end the Early Ambush process.
Abort Window
This parameter determines the amount of time the control panel delays a Burglar Alarm event
from a point with P## Alarm Abort set to Yes. If an alarm silence operation is performed
before this time elapses, the alarm transmission is aborted and the keypad shows an optional
ALARM NOT SENT message. When an alarm transmission is successfully aborted, no event is
written to the control panel event log .
When an abort alarm timer starts, it does not stop until an alarm silence operation is
performed or the time expires.
For SIA CP-01 Compliance:
Abort Window is a required parameter.
NOTICE!
The Fire Supervision Restore Event is part of Fire Events in Routing. If Fire Supervision
Restore Events are needed, simply enable them in Routing.
Default 10 min
Selection: 5 to 30 minutes
Default 1
Selection: 0, 1, 2
0 Keypads do not re-sound the fire trouble tone.
1 Keypads re-sound the fire trouble tone at 12:00 PM if any Fire point that
falls within the scope of a keypad is in an off-normal condition.
2 Keypads re-sound the fire trouble tone at 12:00 AM if any Fire point that
falls within the scope of a keypad is in an off-normal condition.
Default Unique
Selection: Unique or any
Unique The code used to end the timer must be different from the code used to
disarm the area.
Any The timer can be stopped using a different code, or the same code that
disarmed the area.
Default 30 sec
Selection: 15 to 45 sec
NOTICE!
This feature does not apply to Fire Alarms or invisible point alarms.

Table of Contents

Other manuals for Bosch D9412GV4

Related product manuals