EasyManua.ls Logo

Bosch D9412GV4 - Access Control (D9412 Gv4;D7412 Gv4); Door Profile

Bosch D9412GV4
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D9412GV4/D7412GV4/D7212GV4 ACCESS CONTROL (D9412GV4/D7412GV4) | en 195
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
9 ACCESS CONTROL (D9412GV4/D7412GV4)
This section applies only to the D9412GV4 and D7412GV4 Control Panels.
9.1 Door Profile
This programming category is used to:
Assign an area that also activates the D9210C
Assign a point to the door
Program the door state to change the time when the arm state changes
Allow for the Strike relay to activate upon a fire alarm
Programming the Interlock point
Door Number
D# Entry Area #
Assign an area to the door controller. This entry allows the D9210C to be polled, activating
communication to the control panel. This is also the area a user exits when initiating a REX.
D# CC# Scope
NOTICE!
The D9412GV4 supports up to eight doors. The D7412GV4 supports two doors.
Default: Disabled
Selection: Disabled, 1 to 32
1 to 32 The area assigned to the door controller to which the reader allows
access.
Disabled Door controller does not function.
NOTICE!
The D# Entry Area # prompt for the D7412GV4 is limited to the first 8 areas.
NOTICE!
All SDI devices, regardless of area assigned, report to Area 1, Account 1 by default upon SDI
failure. If a D9210C becomes disconnected, an SDI Fail ## and a Missing Point ### Event is
created.
NOTICE!
If the D9210C is not programmed with a D# Entry Area, 9210 NOT READY appears at the
keypad when attempting to add access credentials to a User ID.
Default: 1
Selection: Disabled, 1 to 16 (for D9412GV4), 1 to 8 (for D7412GV4)
1 to 16 Determines the scope of areas to affect the access disarm request if
enabled. Also, determines the keypad to be used when performing Dual
Authentication.
Disabled Only the area assigned in D# Entry Area is disarmed if the user has
access disarm rights. No keypad assignment prohibits Dual
Authentication.