38 en | Panel and Area Wide Parameters D9412GV4/D7412GV4/D7212GV4
F.01U.218.312 | 04 | 2012.03 Program Entry Guide Bosch Security Systems, Inc.
Auto Function Reports
The following prompts support customized routing of Auto Function Reports. Selecting Yes
enables a report to be sent when the event occurs.
RPS Reports
Selecting Yes enables sending a report when the RPS Passcode Event occurs.
Table 3.11 RPS Reports
Point Reports
Selecting Yes enables a report to be sent when the event occurs.
NOTICE!
When activating an on-board relay using remote automation software, the GV4 Series Control
Panels log and print the resulting event as:
Relay 250 (Relay A)
Relay 251 (Relay B)
Relay 252 (Relay C)
Report Selections Report Description
R# Sked Executed Yes, No Sked Executed Event
R# Sked Changed Yes, No Sked Changed Event
R# Execute Fail Yes, No Fail to Execute Event
NOTICE!
"RPS Access Fail" might indicate a wrong RPS passcode when communicating with the control
panel, or a valid RPS session was abnormally terminated. "Remote Reset" indicates a Reset
command was issued from RPS. "Fail to Call RPS" indicates that control panel called RPS, but
was unable to connect.
Report Selections Report Description
R# Log Threshold Yes, No Reports Service Walk Test Start Event
R# Service End Yes, No Service Walk Test End Event
R# Parameters Changed Yes, No RPS Parameters were changed
R# RPS Access OK Yes, No Successful RPS access
R# RPS Access Fail Yes, No RPS failed to access control panel
R# Remote Reset Yes, No Control panel reset by RPS
R# Program Access OK Yes, No Successful local programming
R# Program Access Fail Yes, No Local programming failed