D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 85
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
CC# Assign Door
The door assigned to this keypad is used:
To add door credentials to a user
–With CC## Close Door Warning Tone to annunciate the Door Left Open warning
To enable CC# Dual Authentication for CC# Passcode Functions.
CC# Trouble Tone
Determines whether this keypad, or any keypad with the same address setting, emits the
panel-wide trouble tones (power, phone, SDI bus, and Zonex bus).
Default: Door 1, Area 2 to 8 No Door
Selection: No Door, 1 to 8 on D9412GV4
(No Door, 1 to 2 on D7412GV4)
No Door No door controller is assigned for adding tokens.
1 to 8 The door controller assigned to this keypad is used to read new door
credentials or when Dual Authentication is enabled.
This feature is not available with the D7212GV4. Keep the default setting.
NOTICE!
If a door is not programmed for this prompt and a door is not assigned to the area using
the D# Entry Area in the Access Control section, 9210 NOT READY appears at this keypad
when you attempt to add a user or perform dual authentication.
Assigning a door to a keypad is not necessary for the user to control the door(s) using the
Door Control function. Any door that is active can be controlled by a user who has the
appropriate door control authority. The door control functions are available to a valid
user at any keypad with access to the area where the door is assigned.
The setting of CC# Passcode Function does not affect the ability to add or change door
credentials.
NOTICE!
During the Add User Mode, tokens or cards, door control requests, and RTE/REX do not
function. Put the Door Mode into an unlocked state before adding users if there is heavy
activity for this door.
Default: Yes
Selection: Yes or No
Yes Panel-wide trouble tones sound and visual displays show at this
keypad.
No Panel-wide troubles do not sound. Visual displays still show.
NOTICE!
To meet UL 864 requirements (D9412GV4 and D7412GV4), set CC# Trouble Tone to Yes.
NOTICE!
Panel-wide trouble tones do not include Point Troubles, Buzz on Fault, or (for D9412GV4 and
D7412GV4) Close Door Now.
NOTICE!
Assign two CCs to the same area so one keypad emits the tone and another does not.