D9412GV4/D7412GV4/D7212GV4 Panel and Area Wide Parameters | en 93
Bosch Security Systems, Inc. Program Entry Guide F.01U.218.312 | 04 | 2012.03
3.12 User Interface
Define which functions can be used by each of the fourteen user authority levels. Each user
can be assigned the same or different authority level by area. The user has rights in the area
where the keypad is assigned, based on the authority level assigned to the user’s passcode
for that area.
When the passcode is entered at the keypad, the control panel checks the authority level. The
control panel executes the function only in areas where the passcode has the authority to use
the function.
3.12.1 Commands
Similar to command initiation used in other Bosch Security Systems, Inc. products, the
Commands method provides continuity in the arming commands across product lines and
makes an easy transition for dealers using other Bosch Security Systems, Inc. products. With
commands, the end user presses [COMMAND] and then the numeral of the command to
initiate. For example, [COMMAND][2] arms the perimeter of the area. Some prompts can be
accessed only from a menu. These prompts are indicated by (Menu Function only). To access
these functions, press [MENU], enter the function number, and use the [PREV] and [NEXT]
keys to scroll through the choices.
The D9412GV4/D7412GV4/D7212GV4 Program Record Sheet (P/N: F01U214958) lists the
commands available with the system. Command numbers are shown in the column labeled
Command. If a particular function does not have a command number, it can be accessed only
through the Function List.
If you plan to use only commands to operate the system, and to arm and disarm by entering a
passcode, you do not need to program Custom Function or Function List.
3.12.2 Command Authorization
Programming choices in this section determine if keypad functions are disabled (-), enabled
(E), or passcode (P) restricted.
Table 3.17 Keypad Programming Choices
NOTICE!
The custom functions in Example 2 are compatible between keypad types.
NOTICE!
The GV4 control panel series uses separate keystrokes to program the custom functions that
accurately represent the two separate user interfaces, the D1255 and D1260 keypads.
Custom functions written for the D1255 that use the [PREV], [ESC], and [NEXT] keys do not
work on the D1260.
Custom function written for the D1260 that use the softkeys (located on the sides of the
keypad display) do not work when executed from the D1255 keypad.
Selection Description
- Disable the function panel-wide. The keypad shows NO AUTHORITY if
you access the function using a command or the Function List.
E Enable the function panel-wide. The function can be executed without
entering a passcode.
P Passcode required. When the passcode is entered at the keypad, the
control panel checks the user’s authority level. Refer to
Section 3.12.6 Authority Level Selections, page 102.