EasyManua.ls Logo

Bosch DIVAR IP 7000 2U - Page 44

Bosch DIVAR IP 7000 2U
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Before clear foreign configuration, 2 disks were missing, two were foreign. After clear, the
foreign disks now are shown as unconfigured.
Use the event viewer or MegaCLI to identify the "first failed" disk.
In this example, disk in Slot 4 was first fail, Slot 7 second fail. Click on "second fail" PD7 in the
Logical View and you get in the Physical drive menu. Choose "replace missing PD" and the
correct row for Slot 7 drive and click "go". Ignore the warning.
44 en | Recovering the unit DIVAR IP 7000 2U
2014.12 | V4 | DOC Installation Manual Bosch Sicherheitssysteme GmbH

Table of Contents

Other manuals for Bosch DIVAR IP 7000 2U

Related product manuals