EasyManua.ls Logo

Bosch DNM 60 L - Technical Data; Assembly; Inserting;Replacing the Battery

Bosch DNM 60 L
142 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English | 171 609 929 K06 12.6.06
Technical Data
Assembly
Inserting/Replacing
the Battery
Use only alkali-manganese batteries.
When the symbol appears in the
display 6, the battery must be replaced.
Carefully remove the battery lid 1 with
the battery holder out of the measuring
tool. Pay attention that neither the con-
nection cables of the battery nor the
battery lid are damaged. Excessive
damage on the supporting surface of
the battery lid 1 can lead to faulty
measurements.
Digital level DNM 60 L
PROFESSIONAL
Article number 3 601 K14 000
Length 600 mm
Weight accord-
ing to EPTA-Pro-
cedure 01/2003
0.7 kg
Digital level DNM 120 L
PROFESSIONAL
Article number 3 601 K14 100
Length 1200 mm
Weight accord-
ing to EPTA-Pro-
cedure 01/2003
1.3 kg
DNM 60 L/DNM 120 L
Measuring range 0–36 (4 x 9)
Measuring
accuracy
–0°/90°
1–8
±0.05°
± 0.2°
Levelling
accuracy of the
spirit level
±0.057°
(± 1 mm/m)
Operating
temperature 5 °C ... +50 °C
Storage
temperature
20 °C ... +85 °C
Battery 1 x 9 V 6LR 61
Operating life
time, approx.
200 h
Please observe the article number on the
type plate of your measuring tool. The trade
names of the individual measuring tools
may vary.
OBJ_BUCH-17-004.book Page 17 Monday, June 12, 2006 11:10 A