DS7200V2-EXP | Installation Guide | 4. Reference Materials
EN | 114
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
Table 40: Control Panel Events and Reporting Formats (continued)
Event as shown
in Control Panel
Log
Zone Types
Linked to
Event
87 Missing,Alarm UZ Untyped
Missing Alarm
150 General
Alarm
Zone assigned to zone expander
(wired or RF) not responding to
panel’s status poll while the area
is armed.
6- 24-hr Burg
10-15 Zone
Types
3
88 Missing,Trouble UY Untyped
Missing Trouble
382 Loss of
supervision –
RPM
Zone assigned to zone expander
(wired or RF) not responding to
panel’s status poll while the area
is disarmed.
3-8, 10-15 Zone
Types
6
89 Open,Skd OA Automatic
Opening
403 Automatic
O/C
Opening by Sked. 10
90 Open,RPS OQ Remote
Opening
400
Open/Close
Opening by RPS.
91 Open,Usr OP Opening
Report
401 O/C by
User
Opening by user, ID reported. 10
92 Open,KS OS Opening
Keyswitch
409 Keyswitch
O/C
Opening by Keyswitch. 10
93 Open,Skd,Alarm OR Disarm from
Alarm
403 Automatic
O/C
Opening after Alarm event by
Sked.
10
94 Open,RPS,Alarm OR Disarm from
Alarm
400
Open/Close
Opening after Alarm event by
RPS.
95 Open,Usr,Alarm OR Disarm from
Alarm
401 O/C by
User
Opening after Alarm event, ID
reported.
10
96 Open,KS,Alarm OR Disarm from
Alarm
409 Keyswitch
O/C
Opening after Alarm event by
Keyswitch.
10
97 Reserved
98 Params Changed YG Parameter
Changed
306 Panel
Programming
Changed
Panel Parameters Changed. 12 R
99 Phone Line Fail LT Phone Line
Trouble
351 Telco 1
fault
Phone line voltage less than 3
volts for 40 sec.
12 R S
100 Phone Line Rstl LR Phone Line
Restoral
351 Telco 1
fault
After Phone Line Fail event,
phone line voltage detected at
greater than 3 volts for 40 sec.
12 R S
101 Bad Call to RPS RA Remote
Programmer Call
Failed
413
Unsuccessful
access
Panel attempted call to RPS, but
was unsuccessful.
12 R
102 RPS Access Fail RU Remote
Program Fail
413
Unsuccessful
RPS attempted to connect to
panel but was not successful.
R
103 RPS Access OK RS Valid Remote
Access
412
Successful
Download/Acc
ess
RPS successfully connected to
and disconnected from panel.
R
104 Re-Boot,Panel RR Power Up 305 System
reset
Normal start up or reset after
programming.
R S
105 Re-Boot,Dbus RR Power Up 339 Exp.
Module Reset
Unexpected reset (reboot) from
Data Bus device.
12 R S
106 Output Reset,Usr RO Relay Open 320
Sounder/Relay
Output Reset by User 16 R
107 Output Reset,Skd RO Relay Open 320
Sounder/Relay
Output Reset by Sked 16 R