Page 66 P/N: 4998152533-02 Copyright 2007 Bosch Security Systems, Inc. DS7200V2-UK Installer's Guide
PART IV: CONTROL PANEL PROGRAMMING
Area Option, User #
Address: See Table 26
Default:
User 1:
DS7240V2: 15 (Assigned to Areas 1-4)
DS7220V2: 3 (Assigned to Areas 1 and 2)
User 2: 1 (Assigned to Area 1)
User 3: 1 (Assigned to Area 1)
Users 4-32: 0 (Not assigned to an area)
Selections: 0-15
Enter This Data Digit to Select Options
User Area Options 0 1 2 3 4 5 6 7 8 9 10
11
12
13
14
15
Not Assigned to an Area
Assigned to Area 1
Assigned to Area 2
Assigned to Area 3 (DS7240V2 only)
Assigned to Area 4 (DS7240V2 only)
Assigning PINs to multiple areas allows users to view and operate multiple areas from a single keypad.