Point Programming Items
Programming
Item
Item No. Range
Point Type Point 01 = 9011
Point 32 = 9321
0 = Disabled
1 = Perimeter
2 = Interior
3 = Perimeter Instant
4 = 24-Hour Trouble
5 = Fire Verified
6 = Fire Instant
7 = Panic
8 = Interior Walkthrough
9 = Perimeter Exit Cancel
11 = Momentary Keyswitch
12 = Maintained Keyswitch
13 = 24-Trouble
14 = User Emergency
Circuit Style
Point 01 = 9012
Point 32 = 9322
0 = Dual 2.2 kΩalarm and tamper
circuit
1 = Single 2.2 kΩalarm circuit
Alarm
Verification
Point 01 = 9016
Point 32 = 9326
0 = Disable audio alarm verification
1 = Enable audio alarm verification