18 en | Appendix Easy Series Control Panel
2017.01 | 02 | F.01U.306.216 Quick Installation Guide Bosch Sicherheitssysteme GmbH
Alternate Communication Items
Item
No.
Programming Item Range
293 Route 1 Primary 1 to 99
294 Route 1 Backup
295 Route 2 Primary
296 Route 2 Backup
297 Extend Heartbeat Period 0 = Disabled; 1 to 255 min
RPS Configuration Items
Item
No.
Programming Item Range
118 RPS Passcode 6 digits required, using 0 to 9
and A to F.
224 RPS Automatic Call In Frequency 0 = Never; 1 = Daily
2 = Weekly; 3 = Monthly
225 RPS Automatic Call In Time
(Hours)
0 to 23
226 RPS Automatic Call in Time
(Minutes)
0 to 23
227 RPS Automatic Call in Time (Day
of Week)
0 to 6, where 0 = Sunday and 6
= Saturday
228 RPS Automatic Call in Time (Day
of Month)
1 to 28
229 RPS Automatic Call in Phone
Number/IP Address
Refer to Item Numbers 206-209
for allowed entries.
245 RPS Automatic Call in Method 0 = Phone number; 1 = IP
address
246 RPS Port Number 0 to 655353
Point Report and Restoral Routing
Item
No.
Programming Item Item
No.
Programming Item
301 Point Reports and
Restorals(all)
326 Intrusion Zone Bypass
307 Intrusion Alarm 327 Intrusion Zone Bypass
Restoral
308 Intrusion Alarm Verified 328 Fire Trouble
309 Intrusion Alarm Unverified 329 Fire Trouble Restoral
310 Intrusion Alarm 24-Hr 331 24-Hour Trouble