EasyManua.ls Logo

Bosch FWA 4630 User Manual

Bosch FWA 4630
292 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
FWA 4630
de
Originalbetriebsanleitung
Achsmessgerät
en
Original instructions
Wheel Alignment System
fr
Notice originale
Système de contrôle de géométrie
es
Manual original
de Medicióndel Mecanismo de
Traslación
it
Istruzioni originali
Sistema di controllo assetto
sv
Bruksanvisning i original
Chassimätsystem
nl
Oorspronkelijke gebruiksaanwijzing
Wieluitlijnapparat
pt
Manual original
Sistema de Medição de Chassis
pl
Instrukcją oryginalną
Urządzenie do pomiaru geometrii osi
cs
Původní návod k používání
System měřeni podvozku
tr
Orijinal işletme talimatı
Ön Düzen Ayar Cihazi
zh
原始的指南
轴标准尺寸
Question and Answer IconNeed help?

Do you have a question about the Bosch FWA 4630 and is the answer not in the manual?

Bosch FWA 4630 Specifications

General IconGeneral
BrandBosch
ModelFWA 4630
CategoryWheel Balancers
LanguageEnglish

Summary

Symbols Used

Documentation Symbols

Explains pictograms used for warnings and information.

FWA 4630 Disposal

Guidelines for proper disposal of the FWA 4630 unit.

User Information

Important Notes

Information on copyright, liability, warranty, and user obligations.

Safety Instructions

Crucial instructions for safe operation and connection of the FWA 4630.

Electromagnetic Compatibility (EMC)

Details on EMC directive compliance and potential interference.

Product Description

Intended Use

Specifies the intended application of the FWA 4630 for wheel alignment.

FWA 4630 Description

Overview of the FWA 4630 trolley and its components.

Sensors

Details about the sensors, including fitting, connection, and operation.

Operation

Preparing Measurement Bay

Steps for preparing the measurement bay, including pit and platform checks.

Checking the Pit

Procedure to check and correct height differences in the pit.

Checking Lifting Platform

Ensures measuring and working heights are identical on the lifting platform.

Checking the Vehicle

Checks to perform on the vehicle before measurement, like tire pressure.

Sensor Position

Details on sensor placement on the vehicle.

Vehicle Position on Bay

Instructions on how to position the vehicle correctly on the measurement bay.

Sensor Connection

Steps for connecting sensors in pit and lifting platform versions.

Sensor Connection - Pit Version

How to position and connect sensors in a pit setup.

Sensor Connection - Lifting Platform

Steps for connecting sensors on a lifting platform.

Switch-On and Switch-Off

Procedure for correctly powering the unit on and off.

Online Help

How to access and use the online help feature.

Software Installation

Information regarding the pre-installed system software.

Driving Vehicle onto Bay

Steps for safely driving the vehicle onto the measurement bay.

Attaching the Clamp

Methods for attaching clamps to the wheel, especially universal quick-action clamp.

Universal Quick-Action Clamp

Detailed instructions for using the universal quick-action clamp.

Multiquick Clamp

How to use the Multiquick clamp, including settings and securing.

Plate Size Selection

Guidance on selecting appropriate plates for different vehicle wheelbases.

Attachment of Plates

Instructions for attaching plates to the clamps and aligning them.

Run-out Compensation

Procedure for performing run-out compensation with the Multiquick clamp.

Determine Rolling Distance

How to ensure adequate rolling distance for accurate compensation.

Run-out Compensation Procedure

Step-by-step guide for the run-out compensation process.

Fitting/Removing Brake Clamp

Instructions for attaching and removing the brake clamp.

Fitting/Removing Steering Wheel Arrester

Procedure for fitting and removing the steering wheel arrester.

Program Description

Key Functions

Overview of the main function keys (F1-F10) for operation.

Program Structure

Outlines the sequence of program steps in the FWA 4630 software.

Preparation Steps

Details on customer and vehicle selection, inspection list, and prep operations.

Measurement Routines

Explains standard, quick, and random measurement procedures.

Standard Measurement

Detailed steps for standard measurement including run-out compensation.

Quick Measurement

Describes the quick measurement process with its steps.

Random Measurement

Covers general view, additional quantities, and axle values.

Maintenance Procedures

Information on version record, unit status, and system settings.

Measured Value Displays

Explains how measured values are displayed, including color coding.

Measured Value Display Color

The meaning of colors used to indicate if values are within tolerance.

Front Axle Measured Values

Example display of measured values for the front axle.

Rear Axle Measured Values

Example display of measured values for the rear axle.

Maintenance

Cleaning Procedures

Instructions for cleaning the trolley, plates, and sensors.

Cleaning the Trolley

How to clean the trolley housing and monitor safely.

Cleaning the Plates

Guidance on cleaning the measurement plates.

Cleaning the Sensors

Instructions for cleaning sensor glass filters and avoiding splashwater.

Replacement and Wearing Parts

Table of replacement parts and their order numbers.

Disposal Guidelines

European guidelines for the proper disposal of the FWA 4630.

Checking Sensors

Procedure for checking sensor accuracy using reverse measurement.

Sensor Check - Measurement 1

Steps for performing the first toe and camber check in the direction of travel.

Sensor Check - Measurement 2

Steps for performing the second toe and camber check in the opposite direction.

Enter Measured Values in Table

How to record the measured values from the sensor checks into a table.

Specimen Sensor Check Sheet

An example of a measurement sheet for checking sensor accuracy.

Customer Sensor Check Sheet

A template for customers to record sensor check measurements.

Evaluate Sensor Check Sheet

Instructions on how to evaluate the sensor measurement sheets.

Fault Messages

Lists common fault messages, their possible causes, and remedies.

Additional Fault/Info Messages

Further fault messages and their possible causes and remedies.

Faults in Operating Sequence

Troubleshooting for issues occurring during the system's operation sequence.

Technical Data

Measuring Range

Specifies the measurement ranges for various alignment parameters.

Trolley Dimensions and Weight

Physical dimensions and weight of the FWA 4630 trolley.

Sensor Dimensions and Weight

Physical dimensions and weight of the measurement sensors.

Operating Environment

Recommended temperature and humidity conditions for operation.

Power Supply Unit

Technical specifications for the unit's power supply.

Related product manuals