28
en | Operations Control panels
2019-12 | 03 | F.01U.352.527 Bosch Security Systems B.V.
How to all arm with B94x / B93x, delay
1. Open the menu. Refer to B94x / B93x keypads menu and navigation,
page 19.
2. Press On/Off.
3. Press All On.
4. Press All On Delay.
5. Enter your passcode.
6. Press ENTER.
The exit delay time starts.
7. Leave the area.
P The system is all armed.
If you did not leave the area before the end of the exit delay time,
the system automatically is part armed.
How to all arm with B92x / B91x, delay
1. Open the menu. Refer to B92x / B91x keypads menu and navigation,
page 22.
2. Press 1 to open the on/off menu.
3. Press 1 to open the all on menu.
4. Press 1 to select All On Delay.
5. Enter your passcode.
6. Press ENTER.
The exit delay time starts.
7. Leave the area.
P The system is all armed.
If you did not leave the area before the end of the exit delay time,
the system automatically is part armed.
6.3.2 All arming, instant
All arming the premises without exit delay time.