-20-
Working without Automatic Levelling
Sequence of
actions
Horizontal line
operation
Vertical line
operation
Point
operation
Indicator 3
for battery
capacity
Indicator 4 for
working without
automatic
levelling
Figure
On/Off switch 2 in position
“
”
● ●
Cross-line operation
—
green red F1
Press button for “line &
point” operating mode
6 once
● — —
green red
Press button for “line &
point” operating mode
6 twice
— ● —
green red
Press button for “line &
point” operating mode 6
three times
● ●
Cross-line operation
—
green red F1
The laser lines flash slowly in the “working without automatic level-
ling” mode.
If during work without automatic levelling you switch to the “working
with automatic levelling” mode (On/Off switch 2 in position “
”),
the first combination of this mode’s indicators is always activated.
Automatic Levelling
Working with Automatic Levelling (see figures B1–E1)
– Position the measuring tool on a level, firm support or attach it to the
rotating mount 18 and 19.
– For work with automatic levelling, slide the On/Off switch 2 to posi-
tion “
”.
After switching on, the levelling function automatically compensates
irregularities within the self-levelling range of ±4°. The measuring tool
is levelled in as soon as the laser lines no longer flash.
The laser beam will flash if the automatic levelling is not possible.