30 | English
1 609 92A 23J | (25.8.16) Bosch Power Tools
Measuring accuracy (typical under unfavourable
conditions)
±3.0mm
B)
Lowest indication unit 0.1 mm
Indirect Distance Measurement and Vial
Measuring range 0°–360° (4x90°)
Inclination measurement
Measuring range 0°–360° (4x90°)
Measuring accuracy (typical)
±0.2°
C)/D)/I)
Lowest indication unit 0.1°
General
Operating temperature –10 °C...+45 °C
E)
Storage temperature –20 °C...+70 °C
Relative air humidity, max.
90 %
Laser class
2
Laser type
635 nm, <1 mW
Laser beam diameter (at 25 °C) approx.
–at 10m distance
–at 50m distance
9mm
D)
45 mm
D)
Automatic switch-off after approx.
–Laser
– Measuring tool (without measurement)
20 s
5min
H)
Weight according to EPTA-Procedure 01:2014 0.10 kg
Dimensions
106x45x24mm
Degree of protection
IP 54 (dust and splash proof)
F)
Batteries 2x1.5VLR03(AAA)
Rechargeable batteries
2 x 1.2 V HR03 (AAA)
Battery life, approximately
– Individual measurements
– Continuous measurement
10000
H)
2.5 h
H)
Setting the unit of measure m, ft, in
Data transmission
Bluetooth® Bluetooth® 4.0 (Classic and
Low Energy)
G)
Digital Laser Measure GLM 50 C
OBJ_BUCH-2450-005.book Page 30 Thursday, August 25, 2016 8:38 AM