English | 35
Bosch Power Tools 1 609 92A 23J | (25.8.16)
To select the reference level, press button 4. Use button 3 [+] or button 8 [–] or but-
ton 4 to select the desired reference level. The rear edge of the measuring tool is pre-
set as the reference level every time the measuring tool is switched on.
“Basic Settings”
To enter the “basic configurations” menu (i) press and hold the button 7 [Func].
Select the respective basic configuration and your setting.
To exit the “basic configurations” menu, press the On/Off button 5 [ ] again.
Display Illumination
The display illumination is continuously switched on. When no button is pressed, the
display illumination is dimmed after approx. 20 seconds to preserve the batteries/re-
chargeable batteries.
Measuring Functions
Length Measurement
Select the length measurement .
To switch on the laser beam, briefly press the measuring button 2 [].
To measure, briefly press the measuring button 2 [ ]. The measured value will be
shown at the bottom of the display.
Repeat the above-mentioned steps for each subsequent measurement.
The last measured value is at the bottom of the display, the penultimate
measured value is above it, and so on.
Continuous Measurement (Tracking)
For continuous measurements, the measuring tool can be moved relative to the tar-
get, whereby the measuring value is updated approx. every 0.5 seconds. In this man-
ner, as an example, you can move a certain distance away from a wall, while the actual
distance can always be read.
Select the continuous measurement .
To switch on the laser beam, briefly press the measuring button 2 [].
Move the measuring tool until the required distance value is indicated in the bottom
of the display.