36 | English
1 609 92A 23J | (25.8.16) Bosch Power Tools
Briefly pressing the measuring button 2 [ ], interrupts the continu-
ous measurement. The current measured value will be shown at the bot-
tom of the display. The maximum and minimum measured value appear
above it. Pressing the measuring button 2 [ ] once more, restarts the
continuous measurement.
Continuous measurement automatically switches off after 5 mins.
Area Measurement
Select the area measurement .
Then measure the width and length one after the other as with a length measurement.
The laser beam remains switched on between the two measurements. The distance
to be measured flashes in the indicator for area measurement .
The first measured value is shown at the top of the display.
After the second measurement has been completed, the area will be au-
tomatically calculated and displayed. The end result is shown at the bot-
tom of the display, while the individual measured values are shown
above it.
Volume Measurement
Select the volume measurement .
Then measure the width, length and depth one after the other as with a length meas-
urement. The laser beam remains switched on between the three measurements. The
distance to be measured flashes in the indicator for volume measurement .
The first measured value is shown at the top of the display.
After the third measurement has been completed, the volume will be
automatically calculated and displayed. The end result is shown at the
bottom of the display, while the individual measured values are shown
above it.
Indirect Distance Measurement
For indirect length measurements, three measuring modes are available. Each meas-
uring mode can be used for determining different distances.
The indirect distance measurement is used to measure distances that cannot be
measured directly because an obstacle would obstruct the laser beam or no target
surface is available as a reflector. This measuring procedure can only be used in ver-
tical direction. Any deviation in horizontal direction leads to measuring errors.
Note: Indirect distance measurement is always less accurate than direct distance
measurement. Depending on application, greater measuring errors are possible than
11.623 m
11.623
-64°
m
m1.291
min
max
19.355 m
5.080 m
2
3.810
0.0°
m
1474.8 m
12.700 m
3
11.430
0.0°
m
m10.160