English | 11
Bosch Power Tools 1 609 92A 3UB | (15.3.17)
Measuring accuracy (typical) ±1.5mm
A)
±1.5mm
A)
±1.5mm
A)
Measuring accuracy (typical un-
der unfavourable conditions)
±3.0mm
B)
±3.0mm
B)
±3.0mm
B)
Lowest indication unit 0.1 mm 0.1 mm 0.1 mm
Indirect Distance Measure-
ment and Vial
Measuring range 0°–360°
(4x90°)
0°–360°
(4x90°)
0°–360°
(4x90°)
Gradient measurement
Measuring range 0°–360°
(4x90°)
0°–360°
(4x90°)
0°–360°
(4x90°)
Measuring accuracy (typical)
±0.2°
C)/D)/I)
±0.2°
C)/D)/I)
±0.2°
C)/D)/I)
Lowest indication unit 0.1° 0.1° 0.1°
General
Operating temperature –10 °C...
+45 °C
E)
–10 °C...
+45 °C
E)
–10 °C...
+45 °C
E)
Storage temperature –20 °C...
+70 °C
–20 °C...
+70 °C
–20 °C...
+70 °C
Relative air humidity, max. 90 % 90 % 90 %
Laser class
222
Laser type
635 nm,
<1mW
635 nm,
<1mW
635 nm,
<1mW
Laser beam diameter (at 25 °C)
approx.
–at 10m distance
–at 50m distance
9mm
D)
45 mm
D)
9mm
D)
45 mm
D)
9mm
D)
45 mm
D)
Automatic switch-off after ap-
prox.
–Laser
–Measuring tool (without
measurement)
20 s
5min
H)
20 s
5min
H)
20 s
5min
H)
Weight according to EPTA-
Procedure 01:2014
0.10 kg 0.10 kg 0.10 kg
Digital Laser Measure GLM 50 C GLM 50 C GLM 5000 C