English | 21
Bosch Power Tools 1 609 92A 3UB | (15.3.17)
If there is no value available in the memory, “0.000” is shown at the bottom of the dis-
play and “0” at the top.
The oldest value is located in position 1 in the memory, while the newest value is in
position 30 (when 30 memory values are available). When a further value is saved,
the oldest value in the memory is always deleted.
Deleting the Memory
To delete the content of the memory, press button 7 [Func] and select the memory
function . Then briefly press the On/Off button 5 [ ] to delete the displayed
value.
Simultaneously pressing the button 4 and the On/Off button 5 [ ] deletes all values
stored in the memory.
Adding/Subtracting Values
Measured values or end results can be added or subtracted.
Adding Values
The following example describes the addition of areas:
Measure an area as described in section “Area Measurement”, see page 17.
Press the button 3 [+]. The calculated area and the symbol “+” will be
displayed.
Press the measuring button 2 [ ] to start another area measurement.
Measure the area as described in section “Area Measurement”, see
page 17. Once the second measurement is completed, the result of the
second area measurement is displayed below.To show the end result,
press the measurement button 2 [ ] once more.
Note: With a length measurement, the end result is displayed immediately.
To exit addition, press button 7 [Func].
Subtracting Values
To subtract values, press button 8 [–]. The subsequent steps are the same as for
“Adding Values”.
Deleting Measured Values
Briefly pressing the On/Off button 5 [ ] will delete the last measured value in all
measuring functions. Repeated brief pressing of the On/Off button 5 [ ] will delete
the measured values in reverse order.
143.45 m
2
2
+93.406
m50.039
0.0°
m
2
OBJ_BUCH-2548-004.book Page 21 Wednesday, March 15, 2017 12:57 PM