EasyManua.ls Logo

Bosch GLM 50 C - Page 15

Bosch GLM 50 C
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-15-
Automatic switch-o after approx.
– Laser
– Laser measure (without mea-
surement)
– Display/ Laser measure
(without measurement)
20 s
F
5 min
G
5 min / 15 min
H
Degree of protection IP 54 (dust and
splash proof)
I
Batteries 2 x 1.5 V AAA
(LR03)
Battery life, approximately
– Individual measurements
– Real time measuring
10,000
G
2.5 h
G
Data transmission
Bluetooth® Bluetooth® 4.0
(Classic and Low
Energy)
J
A
The working range increases depending on how well the laser
light is reflected from the surface of the target (scattered, not
reflective) and with increased brightness of the laser point to the
ambient light intensity (interior spaces, twilight). In unfavorable
conditions, e.g., with extreme illumination or a badly reflecting
surface, the measuring range may be limited.
B
In favorable conditions, a deviation influence of ±0.05 mm/m
must be taken into account. In unfavorable conditions, e.g.,
with extreme illumination, badly reflecting surface or the room
temperature deviating heavily from 77 °F (25 °C), the maximum
deviation can be up to ±3.0 mm. Additionally, a deviation influ-
ence of 0.15 mm/m must be taken into account.
C
After calibration at and 90° with an additional grade error of
±0.01°/degree to 45° (max.).
D
At 77 °F (25 °C ) operating temperature.
E
In the real time measuring function, the maximum operating
temperature is 104 °F (40 °C).

Other manuals for Bosch GLM 50 C