30 | English
1 609 92A 4RG | (15.11.2018) Bosch Power Tools
Digital laser measure GLM 500
Measuring range (typical, unfavourable conditions) 20m
B)
Measuring accuracy (typical) ±1.5 mm
A)
Measuring accuracy (typical, unfavourable conditions) ±3.0 mm
B)
Smallest display unit 0.5 mm
Indirect distance measurement and level
Measuring range 0°–360° (4 x 90°)
Inclination measurement
Measuring range 0°–360° (4 x 90°)
Measuring accuracy (typical) ±0.2°
C)D)E)
Smallest display unit 0.1°
General
Operating temperature -10 °C to +45 °C
F)
Storage temperature -20 °C to +70 °C
Relative air humidity max. 90%
Max. altitude 2000 m
Pollution degree according to IEC61010-1 2
G)
Laser class 2
Laser type 635 nm, < 1 mW
Laser beam diameter (at 25 °C) approx.
10m distance 9mm
D)
50m distance 45mm
D)
Automatic switch-off after approx.
Laser 20 s
Measuring tool (without measurement) 5 min
Weight according to EPTA-Procedure 01:2014 0.10 kg
Dimensions 106 x 45 x 24 mm
Protection rating IP54 (dust and splash
proof)
H)
Batteries 2 x 1.5 V LR03 (AAA)

Table of Contents